Understanding the Importance of Stiffness Testing in Material Applications
Stiffness testing equipment plays a critical role in evaluating the bending resistance of paper, board, and packaging materials. Whether used in Medical and Pharmaceutical Packaging, food containers, or industrial laminates, stiffness testing ensures mechanical integrity, functionality, and product performance throughout the supply chain. The standardized assessment of stiffness is essential for quality assurance, regulatory compliance, and product development.
ISO 5628:2019, titled “Paper and board — Determination of bending stiffness — General principles for two-point, three-point and four-point methods”, provides a comprehensive guideline for conducting stiffness tests with precision and repeatability. This article explores how to effectively implement stiffness testing using specialized equipment, with a focus on the Bending stiffness method and applications in healthcare packaging.
Key Concepts of ISO 5628:2019
To select and use the correct stiffness testing equipment, understanding the theoretical background of ISO 5628 is fundamental. According to the standard, bending stiffness (Sb) is derived using the equation:
Sb = (E × I) / b
Where:
- E is the modulus of elasticity
- I is the second moment of inertia
- b is the width of the specimen
This equation reflects how material properties and geometry influence bending resistance. The standard outlines three principal testing modes:
- Measurement of slope from force-deflection or force-angle curves
- Force measurement at a specified deflection
- Deflection measurement at a specified force
Each method has different deflection and rate-of-application recommendations, and the chosen approach must match the desired evaluation objective.
Selecting the Right Stiffness Testing Equipment
For precise and standardized results, using advanced stiffness testing equipment is non-negotiable. ISO 5628 specifies that testing instruments must:
- Allow precise adjustment of bending lengths (±1%)
- Record force vs. deflection or angle with sufficient accuracy (±2.5%)
- Minimize test deviation through proper anvil design
Recommended Solution: Cell Instruments WTD-01 Bending Stiffness Tester
To meet the standard’s stringent requirements, the WTD-01 Bending Stiffness Tester from Cell Instruments is an ideal solution. This device:
- Provides configurable testing angles and deflection rates
- Measures in both directions to average out pre-curvature effects
- Is equipped with real-time force/angle curve display and calculation software
Its precise control and user-friendly interface make it especially suitable for industries requiring strict material performance standards, such as Medical and Pharmaceutical Packaging.
Application in Medical and Pharmaceutical Packaging
Medical and Pharmaceutical Packaging must retain structural stability and be easy to open, fill, and seal. For example, blister packs, paper laminates, and folding cartons require optimized stiffness levels to prevent deformation during processing and storage.
Using Bending stiffness testing:
- Ensures packages can withstand machine handling
- Verifies uniformity across production lots
- Helps in evaluating alternative packaging substrates
Consistent application of ISO 5628-compliant testing procedures protects product integrity, enhances user safety, and supports regulatory approval processes in the pharmaceutical supply chain.
Best Practices for Test Preparation and Execution
Before using stiffness testing equipment, adhere to the following preparation steps for valid results:
- Sampling: Follow ISO 186 for representative sampling
- Conditioning: Use ISO 187 for humidity and temperature stabilization
- Cutting: Ensure specimen edges are clean, straight, and parallel
- Measurement Direction: Test in both machine and cross directions
- Deflection Management: Avoid over-curved samples and maintain test symmetry
Ensure that each test includes both upward and downward deflection to minimize bias. The final stiffness value should be an average from at least ten replicates.
Calculation and Reporting
During testing, record the force-deflection curve. Bending stiffness is calculated from:
- The slope of the linear portion of the force-deflection curve
- Force at maximum deflection
- Or deflection at a specified force, depending on the chosen method
Always report values with three significant figures and document the testing rate, deflection method, and environmental conditions as per ISO 5628.
Why Choose Cell Instruments for Stiffness Testing Equipment?
Cell Instruments specializes in high-performance, compliant testing solutions. The WTD-01 Bending Stiffness Tester exemplifies reliability and precision. Our instruments are:
- Customizable to meet your exact material testing needs
- Backed by technical support and calibration services
- Designed for sectors such as packaging, food, medical, electronics, and quality control agencies

By choosing Cell Instruments, you’re ensuring your testing procedures meet international standards and deliver consistent, actionable data.
Conclusion
Effective use of stiffness testing equipment aligned with ISO 5628:2019 is crucial for evaluating material performance, especially in Medical and Pharmaceutical Packaging. Understanding testing theory, selecting suitable equipment like the WTD-01 Bending Stiffness Tester, and following best practices ensures accurate and reproducible results.
Let Cell Instruments support your quality assurance journey with expert solutions tailored to your industry’s material testing challenges.